Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Dysphagia ; 33(1): 15-25, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28752266

RESUMO

Recent studies have shown an association between alterations in laryngopharyngeal mechanosensitivity (LPMS) and dysphagia, obstructive sleep apnea, and chronic cough hypersensitivity syndrome. A previous reliability study of a new laryngopharyngeal endoscopic esthesiometer and rangefinder (LPEER) showed high intra- and inter-rater reliability; however, its accuracy has not been tested. We performed an accuracy study of the LPEER in a prospectively and consecutively recruited cohort of 118 patients at two tertiary care university hospitals. Most of the patients were suffering from dysphagia, and all of them underwent a standard clinical evaluation and fiberoptic endoscopic evaluation of swallowing with sensory testing (FEESST) using a new sensory testing protocol. The sensory test included determinations of the laryngeal adductor reflex threshold (LART), the cough reflex threshold (CRT) and the gag reflex threshold (GRT). Abnormalities on these reflex thresholds were evaluated for associations with major alterations in swallowing safety (pharyngeal residues, penetration, and aspiration). We evaluated the discriminative capacity of the LPMS test using ROC curves and the area under the curve (AUC-ROC) and its relationship with the eight-point penetration-aspiration scale (PAS) using the Spearman's ρ correlation coefficient (SCC). We found a positive correlation between the PAS and LART (SCC 0.47; P < 0.001), CRT (SCC 0.46; P < 0.001) and GRT (SCC 0.34; P = 0.002). The AUC-ROC values for detecting a PAS ≥7 were as follows: LART, 0.83 (P < 0.0001); CRT, 0.79 (P < 0.0001); GRT, 0.72 (P < 0.0001). In this study, the LPEER showed good accuracy for evaluating LPMS. These results justify further validation studies in independent populations.


Assuntos
Transtornos de Deglutição/diagnóstico , Deglutição/fisiologia , Endoscopia/normas , Limiar Sensorial/fisiologia , Endoscopia/métodos , Engasgo/fisiologia , Humanos , Laringe/fisiopatologia , Masculino , Faringe , Reprodutibilidade dos Testes
2.
Eur Arch Otorhinolaryngol ; 274(7): 2861-2870, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28341965

RESUMO

BACKGROUND: There are not reliable methods for measuring laryngo-pharyngeal mechano-sensitivity (LPMS). We aimed to determine the reliability of a new method for measuring LPMS using a new laryngo-pharyngeal esthesiometer (LPEER) in a prospective cohort of dysphagic stroke and non-dysphagic patients. The patients underwent clinical and endoscopic evaluations of swallowing (FESSST). The LPMS assessments consisted of measurements by an expert and a novel rater of the laryngeal-adductor reflex threshold (LART), cough reflex threshold (CRT) and gag reflex threshold (GRT) using the LPEER. We assessed the Bland-Altman limits of agreement, the intraclass correlation coefficients (ICCs) and Spearman correlation coefficients (SCCs). For the inter-rater comparisons, we contrasted the expert and novel raters. A total of 1608 measurements were obtained from 34 dysphagic stroke patients and 33 non-dysphagic patients. The intra-rater ICCs for all reflex thresholds were >0.90. The inter-rater ICCs were 0.87 for the LART, 0.79 for the CRT and 0.70 for the GRT. The intra-rater SCCs for all reflex thresholds were above 0.88 (P < 0.0001). The inter-rater SCC were 0.80 for the LART, 0.79 for the CRT and 0.70 for the GRT (all P < 0.0001). The Bland-Altman plots revealed good agreement for the LART and CRT and moderate agreement for the GRT. The median normal value was 0.14 mN for the LART, 4.4 mN for the CRT and 11.9 mN for the GRT. The median thresholds values in patients with aspiration were LART: 1.31 mN; CRT: 32.9 mN and GRT: 32.9 mN (all P < 0.006 vs normal thresholds). The LPEER exhibited substantial to excellent intra- and inter-rater reliability.


Assuntos
Deglutição/fisiologia , Engasgo/fisiologia , Adulto , Tosse/diagnóstico , Tosse/fisiopatologia , Endoscopia/métodos , Feminino , Humanos , Doenças da Laringe/diagnóstico , Doenças da Laringe/fisiopatologia , Laringe/fisiopatologia , Masculino , Doenças Faríngeas/diagnóstico , Doenças Faríngeas/fisiopatologia , Faringe/fisiopatologia , Estudos Prospectivos , Reprodutibilidade dos Testes , Limiar Sensorial
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...